FORMATION AND OPENING OF TILTED CRACKS IN COMBINED FIBER REINFORCED CONCRETE BEND ELEMENTS

new site

This site is no longer updated!
The new website of the magazine is located at https://visnyk.lnup.edu.ua/

 

Visnyk LNAU: Architecture and Farm Building 2017 №18: 40-47

FORMATION AND OPENING OF TILTED CRACKS IN COMBINED FIBER REINFORCED CONCRETE BEND ELEMENTS

V. Bilozir, PhD
Lviv National Agrarian University

https://doi.org/10.31734/architecture2017.18.040

Annotation

The test program presented in the table provides for the production and testing of samples reinforced with Ø5Bp-1 reinforcement and anchor fibers of Ukrainian production of 50 x 1 mm, according to the scheme of a single-pass beam with a cross-section of 100 x 50 mm loaded by lumped forces in a run equal to 900 mm. The distance from the extreme stretched fibers to the center of the weight of the rod - 15 mm. The controlled parameters during the tests were deflection, deformation of the concrete, the width of the opening of sloping cracks.

Parameters of experimental models

Sample sizes

Class of concrete

Сut-off run a, mm

Percentage of fiber reinforcement µfv, %

0

0,7

1,25

1,8

1200х100х50

С 16/20

110

Б 1.1

F 2.1

F 3.1

F 4.1

220

Б 1.2

F2.2

F 3.2

F 4.2

The measured widths of the opening of sloping cracks depended on the amount of fiber reinforcement and the size of the cut-off run. It has been experimentally discovered that, with an increase in cut-off run, the width of the opening of sloping cracks increased by an average of almost two-fold. It was characteristic that during the cut-off run a = 2,2d the cracks developed quite intensively, according to our experiments, the cracking forces were not much smaller than the destructive ones. When cut-off run a = 1,1d cracks developed less intensively, compared with the beams, in which the cut-off run was equal to a = 2,2d.

Experimental and theoretical studies of features combined fiber-reinforced beams on the fiber of Ukrainian production in the area of the transverse forces lead to the following conclusions:

  • the fiber positively affects the crack resistance of inclined beams;
  • the formation of inclined cracks should be checked according to the formula SNiP 03.01-84 *, taking into account the coefficient kf,cr  as determined by us;
  • width of crack opening advisable to determine given us an improved coefficient k1;
  • the theoretical parameters of crack resistance, as determined by us, are 1 ... 4% less than experimentally obtained, which is acceptable for design practice.

Key words

bend elements, steel fiber, tilted cross section, cracks formation, crack opening

Full text

pdf

Link

  1. Priev B.A. Strength and crack resistance of steel-fiber-concrete thin-walled bent elements by inclined sections: Abstract for the PhD degree / B.A. Priev. Moscow, 1989. 20 p.
  2. Recommendations for the design and manufacture of steel fiber concrete structures. M.: NIIZHB, 1987. 148 p.
  3. Steel fiber concrete structures: SP 52-104-2006: Introduced on September 1, 2006. M.: FSUE SRC “Construction”, 2007. 73 p.
  4. Constructions of buildings and structures. Guidelines for the design and manufacture of steel-fiber reinforced concrete structures: DSTU-N B V.2.6-78: 2009. Introduced on 01.01.2010. K.: Minregionbud of Ukraine, 2009. 43 p.
  5. Vandewalle L. Recommendations of RILEM TC162- TDF: Test and Design Methods for Steel Fibre Reinforced Concrete: bending test (final recommendation) / L. Vandewalle // Materials and Structures. 2002. Vol. 35. P. 579-582. https://doi.org/10.1617/13884 